| 1030nm PM Optical Circulator (TGG-Based) | |||
| Features | Applications | ||
| Low Insertion Loss | Fiber Amplifier | ||
| High Return Loss | Testing Instrument | ||
| High Isolation | Fiber Sensor | ||
| High Stability & Reliability | Medical Equipment | ||
| Specifications | |||
| Parameters | Unit | Value | |
| Center Wavelength | nm | 1030 | |
| Operating Wavelength Range | nm | ±5 | |
| Typ. Peak Isolation | dB | 25 | |
| Max. Isolation at 23℃ | dB | 22 | |
| Typ. Insertion Loss at 23℃ | dB | 1.3 | |
| Max. Insertion Loss at 23℃ | dB | 1.5 | |
| Min. Extinction Ratio at 23℃, only for PM | dB | 20 | |
| Min. Return Loss(Input/ Output) | dB | 45 | |
| Min. Cross Talk | dB | 45 | |
| Max. Average Optical Power | W | 20 | |
| Max. Peak Power for ns Pulse | kW | 10 | |
| Max. Tensile Load | N | 5 | |
| Package Dimension | mm | 64x28x26 | |
| Operating Temperature | ℃ | +10~+50 | |
| Storage Temperature | ℃ | 0~+60 | |
| Ordering Information | ||
| PMCIR-1111-23-444-567-888-99AA | ||
| 1064 | -Center Wavelength: | 1064=1064nm, 1030=1030nm, 980=980nm | 
| 2 | -Port Type: | 3=3-Port | 
| 3 | -Axis Alignment for PM: | F=Slow axis working, Fast axis blocked, B=Both of axis working, N=No axis | 
| 444 | -Fiber Type: | 001=PM1550, 002=PM1310, 003=PM980, 004=Hi1060, 008=SMF-28E | 
| 6 | -Package Dimension: | 0=64x28x26mm, S=Specified | 
| 6 | -Pigtail Type: | 0=250μm bare fiber, 1=900μm loose tube | 
| 7 | -Fiber Length: | 0=0.8m,1=1m | 
| 888 | -Connector Type: | 0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC, N=None | 
| 99 | -Average Power: | 00=500mW, 01=1W, 02=2W,......, 05=5W, 10=10W | 
| AA | -Peak Power: | 10=10kW, 20=20kW |