Specifications

Parameters

Unit

Values

Grade

-

P

Center Wavelength

nm

1064

Operating Wavelength Range

nm

±20

Typ. Insertion Loss at 23℃

dB

0.6

0.7 

Max. Insertion Loss at 23℃

dB

0.8

0.9 

Min. Extinction Ratio at 23℃

dB

22

20 

Min. Directivity

dB

50

Min. Return Loss

dB

50

Max. Optical Power(CW)

mW

300

Max. Tensile Load

N

5

Fiber Type

Port 1 & 2

-

PM Panda fiber

Port 3

SMF-28E, Hi1060 or PM Panda fiber

Operating temperature

-5~+70

Storage  temperature

-40~+85

For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower.

The default connector key is aligned to slow axis.

More Detail

Routing path is from port 3 to 1,2, Here are three options of polarized state from Port 3 to Port 1 & 2:

Option 1, SM to PM,

Port 3, Circularly polarized light in,

Port 1: 50%,Linear polarized light out, through slow axis, Port 2: 50%,Linear polarized light out, through slow axis

Option 2: PM to PM, port 3 is slow axis 0° aligned to port 1

1.Port 3, Linearly polarized light in, through slow axis,

Port 1: 100%,Linear polarized light out, through slow axis, Port 2: 0%

2.Port 3,Linearly polarized light in, through fast axis,

Port 1: 0%, Port 2: 100%,Linear polarized light out, through slow axis

Option 3:PM to PM,port 3 is slow axis 45° aligned to port 1

1.Port 3, Linearly polarized light in, through slow axis,

Port 1: 50%,Linear polarized light out, through slow axis, Port 2: 50%,Linear polarized light out, through slow axis

2.Port 3, Linearly polarized light in, through fast axis,

Port 1: 50%,Linear polarized light out, through slow axis, Port 2: 50%,Linear polarized light out, through slow axis

Ordering Information

    PBS-1111-23-444-555-678-999

1111

-Center Wavelength:

1550=1550nm,1310=1310nm,......,0980=980nm

2

-Grade:

P=Perfect grade, A=A grade

3

-Option for Port 3 to 1,2:

1=Option 1, 2=Option 2, 3=Option 3

444

-Fiber Type for Port 3:

001=PM1550, 002=PM1310, 003=PM980, 004=Hi1060, 008=SMF-28E

555

-Fiber Type for Port 1.2:

001=PM1550, 002=PM1310, 003=PM980, 004=Hi1060, 008=SMF-28E

6

-Package Dimension:

0=φ5.5x35mm, 1=φ5.5x50mm, S=Specified

7

-Pigtail Type:

0=250μm bare fiber, 1=900μm loose tube

8

-Fiber Length:

0=0.8m,1=1m

999

-Connector for Port 1,2,3:

0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC, N=None

Ruik-tech Communication (Dongguan) Co.,LTD.
Add:4F, Bldg. A, ZhaoHe Industrial Park, #39 Wentangcixia 1st. Rd., Dongcheng District, Dongguan, China 523121.
Tel: +86-769 28337151   +86-769 28337215

Fax: +86-769 23322846
Bussiness:sales@ruik-tech.com
Technical Support:tech@ruik-tech.com
Website:www.ruik-tech.com
           
Hot tags: PM Optics Fiber Circulator  PM Fiber Coupler PM Fused Coupler High Power Fiber Isolator  PM fiber combiner  Patchcord Pump Laser Protector In-line Polarizer  Polarization Maintaining Fiber  Component  PM PLC PM CWDM/DWDM Fiber Optic Current Transducer(FOCT) High Power Fiber Component  Polarization Maintaining Fiber Attenuator(VOA) PM Optical Switch
CopyRight © 2018 Ruik-tech Communication Co.,LTD.   粤ICP备17056573号

Online
Service

ConsultationTime:9:00-18:00

Select customer service:

Hot
Line

0769-28337151
7*24H Service

Follow
Us

Website
TOP